How To Troubleshoot A Beckett Oil Burner
If you are having trouble with your Beckett oil burner then you will need to find out what is wrong with it by troubleshooting different parts of the burner. There are many different things that can go wrong and will make your burner fail, so it is very important to read carefully as well as repair the burner the same way.
The first thing you will need to do is make sure that you know where all the parts are we are going to describe and if you don’t and even reading this makes you nervous it maybe best that you just hire someone that is licensed in repairing oil burners. Of course you could be a season repair professional and might be looking for some Beckett oil burner troubleshooting tips as well just to make your service calls go easier. Whatever the case maybe you will need to know what and where the parts are to repair a Beckett burner.
Problem: “My Beckett Burner has a clogged nozzle and won’t ignite”
Solution: You will need to either replace the oil burner nozzle or learn how to clean a oil burner nozzle so that you can get the fuel through the nozzle with the intended flow. Buying a brand new replacement Beckett oil burner nozzle is recommend choice of many oil heating service professionals, but if you are low on money and like to tinker with things then go on ahead and try to clean it.
Problem: “My Beckett Oil Burner has no spark and won’t light”
Solution: This could be caused by a bad transformer or even electrodes that are not positioned or even adjusted correctly. You will want to make sure that your transformer is good and your electrodes have been properly adjusted.
Problem: “How do I bleed the air out of my Beckett burner oil lines”
Solution: Hit the reset button on the motor while opening the bleed screw on the pump. It is a good idea to make sure you loosen the bleed screw before hand to make sure its not tight, then just hand tighten it, so when you hit the reset button you can just open the Beckett burner bleed screw a half turn and let the air out of the line. The bleed screw is located in the front or the side of the oil pump on the burner.
Problem: “The flame on my Beckett burner is yellow not blue”
Solution: This means that you need to adjust the air intake on the fan. You can do that by adjusting the squirrel cage baffles located on the side of the burner.
Problem: “How do I change my oil filter on my beckett Oil Burner”
Solution: If you need to replace the oil filter on you Beckett burner you can do so by removing the bolt that holds the cover over the filter. Once have removed the bolt you can remove the filter cylinder and then pull the filter out and replace it with a new one.
Problem: “My Beckett Oil Burner is blowing black smoke”
Solution: If you are a homeowner then its seriously time to call in a heating professional to have your burner cleaned and adjusted. If you are a heating professional and are clueless because you have never really worked on Beckett oil burners then you will need to adjust the flame, air, intake and possible clean the boiler. It might be a good idea to get some kind of factory training.
Regular Maintenance Tips:
According to the manufacturer, it is recommended for the owner to hire a service professional to perform a regular maintenance on a yearly basis. It is also strongly suggested not to tamper with or make any incorrect adjustments on the unit, controls and any other critical area and parts by owner’s hands because it could lead into further problems such as asphyxiation, explosion or fire. Always make sure that a qualified service technician starts the work on the jobsite.
This is because operation and adjustment of the oil burner requires many hours of in-depth technical training and skillful use of combustion test instruments and other test equipment, and these could not be easily acquired by regular customer over the books or any other online resources.
However, as an owner of this burner you can do a few basic things before you make a service call:
– Check the outside oil supply line. It is visible and usually transparent pipe, and you can inspect any signs of leakage around the area.
– Also check the oil supply system. All fittings should be leak-tight. The supply lines should be free of water, sludge and other restrictions.
– If you can, verify the nozzle is the one originally specified by the appliance manufacturer. Sometimes it can result in malfunction or poor performance having the nozzle of different specifications from the same manufacturer.
– Inspect the igniter spring contacts. Clean or replace if corroded.
– Inspect all gaskets. Replace any that are damaged or would fail to seal adequately.
Here are manual steps on how to replace Beckett Oil Burner Blower Wheel (Note: This is only for your reference. Do not attempt to do it yourself. Always contact your qualified service technician or serviceman first):
woke up no heat, 9 year old becker boiler showed blinking green light. i have oil and it was tuned up in november, hit reset seems fine.???any thoughts thanks,brian
My boiler is heating the water but not the house
I have replaced the eye, nozzle, motor, burner cap, electrodes, thermostat and reset box. The furnace works for a little while then quits. What else could be wrong. The filter is clean too.
THE TRANSFORMER IS INTERMITTENT OR HAS FAILED
Beckett Burner shuts off and leaves a constant yellow light on the transformer. She’ll run for a day or two and the same thing happens.
What could it be or what troubleshooting site can I go to?
Thanks
TRANSFORMER
Did you ever find out your problem my furnice is doing same thing its only 2 yrs old just had it all cleaned ty
Oct. 28,2013 12:00
I have no hot water.
How do I fill up the furnace with water? It is a Beckett-
Honeywell? I can’t find a web site to show me and I don’t
want to wait on the phone. Thanks, Eileen
21805 motor
Motor not functioning. Does it have a reset button? The 3 long bolts on the side will not budge. Any ideas?
My burner does not run through a straight heating cycle ? It keeps timing out and turning back on to reach its current temperature. Just started doing this after recently having it serviced ? The service repair man does not know why its doing it ? Do you have any suggestions ? It also dry started recently making a lout bang with blue smoke. The repair man put in a new transformer.
My Beckett Burner has a faltering flame. ( this is on a New Yorker boiler, mod FR 147, nearly 30 years old) It “puffs” and runs rough. As it runs, the barometric damper flaps dramatically. The smoke pipe is hooked to a power vent. 2 weeks ago(1/07/2014), it was running rough like this and I changed the tank filter and the nozzle. I also cleaned the electrodes. After this, it ran smoothly until yesterday (1/21/2014), when it started doing the same thing, as though there was an interruption in the firing by the igniter or the fuel was not constant and steady. I changed the nozzle again (1.10 80 degree A)and run it. Still running the same so I changed the igniter (Carlin 41000)and cleaned the fire eye. It is still doing the same thing. I have not changed the screen in the pump. Do you have any suggestions?
When someone writes an paragraph he/she maintains the idea of a
user in his/her brain that how a user can know it.
Therefore that’s why this piece of writing is amazing.
Thanks!
Had tho replace control mod on my unit now blower doesn’t work
My heater runs for a little while, then kicks the reset button. No heat. I have changed the nozzle and filter. What else could it be. I see and hear it running but doesn’t fire up; keep kicking the reset button.
I have a Beckett AFG oil furnace and it blows cold air. I have fuel and as I said the blower works.
My furnace has power and keep tripping reset. When reset is pushed nothing happens no motor or pump then after about 30-45sec it resets again
My lights. And goes off but want relight until it cools down under 200
My burner lights but want relight until it cools below 200 degrees