Plumbing, Heating and Pool Repair Guides

How To Troubleshoot A Beckett Oil Burner

/
/
/
20877 Views

If you are having trouble with your Beckett oil burner then you will need to find out what is wrong with it by troubleshooting different parts of the burner. There are many different things that can go wrong and will make your burner fail, so it is very important to read carefully as well as repair the burner the same way.How To Troubleshoot A Beckett Oil Burner

The first thing you will need to do is make sure that you know where all the parts are we are going to describe and if you don’t and even reading this makes you nervous it maybe best that you just hire someone that is licensed in repairing oil burners. Of course you could be a season repair professional and might be looking for some Beckett oil burner troubleshooting tips as well just to make your service calls go easier. Whatever the case maybe you will need to know what and where the parts are to repair a Beckett burner.

Problem: “My Beckett Burner has a clogged nozzle and won’t ignite”

Solution: You will need to either replace the oil burner nozzle or learn how to clean a oil burner nozzle so that you can get the fuel through the nozzle with the intended flow. Buying a brand new replacement Beckett oil burner nozzle is recommend choice of many oil heating service professionals, but if you are low on money and like to tinker with things then go on ahead and try to clean it.

Problem: “My Beckett Oil Burner has no spark and won’t light”

Solution: This could be caused by a bad transformer or even electrodes that are not positioned or even adjusted correctly. You will want to make sure that your transformer is good and your electrodes have been properly adjusted.
Beckett Oil Burner Bleed Screw
Problem: “How do I bleed the air out of my Beckett burner oil lines”

Solution: Hit the reset button on the motor while opening the bleed screw on the pump. It is a good idea to make sure you loosen the bleed screw before hand to make sure its not tight, then just hand tighten it, so when you hit the reset button you can just open the Beckett burner bleed screw a half turn and let the air out of the line. The bleed screw is located in the front or the side of the oil pump on the burner.

Problem: “The flame on my Beckett burner is yellow not blue”

Solution: This means that you need to adjust the air intake on the fan. You can do that by adjusting the squirrel cage baffles located on the side of the burner.

Problem: “How do I change my oil filter on my beckett Oil Burner”

Solution: If you need to replace the oil filter on you Beckett burner you can do so by removing the bolt that holds the cover over the filter. Once have removed the bolt you can remove the filter cylinder and then pull the filter out and replace it with a new one.

Problem: “My Beckett Oil Burner is blowing black smoke”

Solution: If you are a homeowner then its seriously time to call in a heating professional to have your burner cleaned and adjusted. If you are a heating professional and are clueless because you have never really worked on Beckett oil burners then you will need to adjust the flame, air, intake and possible clean the boiler. It might be a good idea to get some kind of factory training.

Regular Maintenance Tips:

According to the manufacturer, it is recommended for the owner to hire a service professional to perform a regular maintenance on a yearly basis. It is also strongly suggested not to tamper with or make any incorrect adjustments on the unit, controls and any other critical area and parts by owner’s hands because it could lead into further problems such as asphyxiation, explosion or fire. Always make sure that a qualified service technician starts the work on the jobsite.

This is because operation and adjustment of the oil burner requires many hours of in-depth technical training and skillful use of combustion test instruments and other test equipment, and these could not be easily acquired by regular customer over the books or any other online resources.

However, as an owner of this burner you can do a few basic things before you make a service call:

– Check the outside oil supply line. It is visible and usually transparent pipe, and you can inspect any signs of leakage around the area.
– Also check the oil supply system. All fittings should be leak-tight. The supply lines should be free of water, sludge and other restrictions.
– If you can, verify the nozzle is the one originally specified by the appliance manufacturer.  Sometimes it can result in malfunction or poor performance having the nozzle of different specifications from the same manufacturer.
– Inspect the igniter spring contacts. Clean or replace if corroded.
– Inspect all gaskets. Replace any that are damaged or would fail to seal adequately.

Here are manual steps on how to replace Beckett Oil Burner Blower Wheel (Note: This is only for your reference. Do not attempt to do it yourself. Always contact your qualified service technician or serviceman first):

 

233 Comments

  1. the motor on my beckett oil burner is not turning on, I seem to have power all throughout the system, the unit is 22 years old, but was running fine up until yesterday. when I hit the reset button or turn the power on and off, everything is clicking on sending power through the system. it the motor bad, capaciter, fuse???

    • TRY MAKING SURE THAT YOUR PILOT LIGHT IS STAYING LIT, IF NOT IT WILL GO INTO LOCKDOWN MODE. I AM NOT AN EXPERT JUST A SUGGESTION ONLY.

  2. I have a beckett that’s 2yrs old. I ran low on oil and think the filter was plugged, replaced it. Now how do I get the thing to start pumping? I hit the reset once now it won’t do anything! Cycled power and shut and adjusted thermostat and got it to try once, Help!!!

  3. when i fire up my burner I get a strong smell in my home of fuel oil.
    and if I turn on any exsaust fan in the home I get a strong smell of fuel oil,checked all line and under home no leaks.
    wonder if oil has leaked in to my combustion chamber,or flame needs to be adjusted

  4. i changed the oil filter and i also changed the filter on the pump and along with a new nozzel but the oil tank filter will not fill its self up. its doing it slowly drops only and its taking to long

  5. Can you suggest why a Beckett burner model MSR spec 115-255B serial#1200 would be equiped with W606 electrodes this type and style belong to a (Wayne) burner please respond ASAP if possable………thank you

  6. Have a Beckett AFG, older model…while changing air filter noticed a on/off switch to the right of the air intake/blower ?? when running, should this switch be on or off ??

  7. I have a beckett oil burner model 7505 and the interrupted ignition oil primairy is a 7505B thethermostat clicks on but the furnace does not come on the thermostat is new. could there be a problem with the interrupter?

  8. Mike:
    I have a beckett oil burner model AFG year June 6, 2005 and it starts and stops each time it starts, about two times and then it stays on.
    Any suggestions ?

  9. I have a 10 year old Beckett AFG which has had a few repairs since bought. I recently replaced the nozzle and filter, the strainer was cleaned a couple of years ago. I can hear and see the flame going out every approximately 5 seconds. It just continuosly cycles like this. My oil tank is getting pretty low in oil. Is it possible that the oil level in the tank might do this, or is there other things I can check. I am also getting some oil smell but would assume that may be because of the inefficient flame condition. Thanks.

    • my beckett burner shuts down 35 seconds after depressing reset button.i have replaced the following with new parts,control box, igniter transformer, cad eye,burner nozzle,electrodes, wall thermostat, and it still shuts down after 35 seconds.

  10. my problem is this, my oilfired hotwater heater sometimes fires and sometimes doesn’t. When it doesn’t I have to press the red reset button then give the transformer a good whack. I tried a screwdriver beteen electrode springs and the spark seemed pretty good don’t know if the whack is affecting the trans or the motor. Just put in a new nozzle recently, any thoughts?

  11. My Beckett Oil burner is 8 years old I have had it serviced so many times and repaired I lost track could have bought a new one. The problem is I only use it mostly in my weekend home. When I leave I drop it to 55 and it never goes on. When im in the house and leave it on 70 goes on & off but for some reason when its off for a long period of time never fires up again. I changed almost every part any help???????

  12. I have a Beckett oil furnace (6 years old). Nothing but trouble from Sears technicians. Could write a book on things they screwed up since I signed 5 yr. maintainence agreement. Latest problem is the filter is solid black after running a couple days. Sears came in last summer, cleaned all duct work and adjusted everything. There is no change this year & I don’t want them back. Any ideas of the cause?

    • Problem is with your tank ,if the filter is blocked in 2 days it a mess . Most likely you need a new oil tank .

  13. My Becket burner starts and runs for 5 minutes then shuts down
    and the fan keep running then the burners starts and goes for 5 minutes more what causes this problem
    thanks nelson

Leave a Comment

Your email address will not be published.

This div height required for enabling the sticky sidebar
Ad Clicks : Ad Views : Ad Clicks : Ad Views : Ad Clicks : Ad Views : Ad Clicks : Ad Views : Ad Clicks : Ad Views : Ad Clicks : Ad Views :