Latest Discussions
-
Topic: Toyotomi Oil Miser Water Heater Review Freshness: 20 hours 14 minutes ago Reply
Mark Weldon wrote: Mr. Davidson, I’m looking to purchase one of these units and up here I seem to have to first buy the unit and vent kit seperately ( costing me more $ ) then the original price quoted is too low and the dealer seems like they want to charge me more money. Could you please enlighten me to the cost of the om -148 toyo water heater in your neck of the woods so I can see if what I’m paying is legit or I’m being Gouged ? Thanks Mark
Topic: My Pool Water Is Cloudy Freshness: 1 day 10 hours ago Reply
Joseph wrote: HI, Have you tried using pool flock? This will help get the water sparkling again, Let me know if you need more help. Joseph
Topic: My Pool Water Is Cloudy Freshness: 1 day 10 hours ago Reply
Gedit wrote: Hi, In my pool the water is not so crystal clear. I wash my filter about every week and it runs daily from 9-5. Still when I use an Algae brush, a cloud of green dust will puff up which makes the water looks even worse. I have adjusted the chmicals and I do so weekly, but to no avail. I also have the Great White Vac cleaner running all day with the pump but it seems to do nothing much… How do I get sparkling clear water back again? Thanks, Gedit
Topic: Top Three Ways To Unclog Your Bathtub Drain Freshness: 1 day 13 hours ago Reply
sosewlinda@gmail.com wrote: Thank you I will give this a try and get back to you.
Topic: Top Three Ways To Unclog Your Bathtub Drain Freshness: 1 day 15 hours ago Reply
Redwood wrote: In the basement follow the drainpipe from the first floor tub to whee it connects to other drains that are not affected by the clog. There is no noubt in my mind that the second floor tub connects before that point. You will have to effectively snake the distance from the first floor tub to where it connects with the other drains that are not affected.
Topic: Top Three Ways To Unclog Your Bathtub Drain Freshness: 1 day 23 hours ago Reply
sosewlinda@gmail.com wrote: i went into basement and took out p trap for apartment 23 tub. . water came out. If i leave trap open the water in apartment 27 up stairs does not drain into bottom apartment tub 23. when i snaked in apartment 27 it went down about 8 feet. any other suggestions?
Topic: Stiebel Eltron Tempra 15 Electric Tankless Water Heater Review Freshness: 2 days 9 hours ago Reply
Redwood wrote: Hi Jay, The answer I’m going to give you will probably render the point of this being enclosed in a closet pointless. But, yes you can enclose this unit in a closet. Now for the kicker! It sounds like you are planning on using this unit for a whole house water heater and I would consider it to be woefully inadequate in that application. In fact even most larger electric tankless water heaters yield disappointing results in whole home applications except in the extreme southern states where winter water supply temperatures are still quite high. At it’s best scenario hooked up to 240 vac power it will provide 3 gpm of hot...
Topic: How To Fix Seven Types Of Leaky Faucets Freshness: 2 days 10 hours ago Reply
Redwood wrote: Hi Darren, You could cetainly attempt to change the washers however, depending on age, water conditions, and the condition of your hose bibb it may not work. The stem if replacement is needed will probably not be available and the seat on these cheap valves cannot be replaced. Many times the water leaking past the seat and washer eodes the seat leaving a groove which will only tear up a new washer after a few uses. It is possible to use a seat cutter to smooth the seat. What it all boils down to if it was me I would not bother trying to play with the old valve but instead would go ahead and replace it. They are cheap valves and are really not designed for...
Topic: How To Fix Seven Types Of Leaky Faucets Freshness: 2 days 10 hours ago Reply
Redwood wrote: Check for damage to the cartridge o-ring.
Topic: How To Fix Seven Types Of Leaky Faucets Freshness: 2 days 10 hours ago Reply
Redwood wrote: Hi Brady, See my reply to Larry above… Your timeing made repying easy, it’s not usual that I get a 2 for 1 sale. I hope that helps you out.
Topic: How To Fix Seven Types Of Leaky Faucets Freshness: 2 days 10 hours ago Reply
Redwood wrote: Hi Larry, When you say that you swapped cartriges I’m not sure if you swapped the hot & cold or, swapped in new. If you swapped sides I would definitely try new and see what happens then. The new cartridges O-Ring should be lubricated with a grease per Moen specs when installed. The cartridge relies on the O-Ring to seal against leakage and it is possible that it may have been damaged on insertion into the valve body. The bore of the faucet body may also have some debris from the old O-Ring bonded to the bore causing a rough spot or the bore may have been scratched or eroded from the leak also. If the bore of the faucet body is not smooth where...
Topic: How To Fix Seven Types Of Leaky Faucets Freshness: 3 days 0 hours ago Reply
brady wrote: Larry, I am having the same trouble. I just replaced both cartridges in my bathtub and it is still leaking.
Topic: Top Three Ways To Unclog Your Bathtub Drain Freshness: 3 days 3 hours ago Reply
Redwood wrote: Your snake was either not long enough to reach the clog or, it did not go in the right direction. Have you snaked from the first floor tub?
Topic: Burnham Boiler: MPO Boiler Review Freshness: 3 days 4 hours ago Reply
jd wrote: Here in Alaska we run into cold weather issues often w/ oil. Check 1. Is the fuel oil supplied type 1 or type 2? 2. Do you have a Tiger Loop installed on the Burner? These help warm the oil before it hits the nozzle. 3. Do you have a water filter? 4. Have you tried wrapping a heat trace on the fuel supply line with poly insulation around it? Usually if a burner works adequatly in warm temps, it will with correct protection on the fuel supply. In extreme temps a Day tank can be used, ensuring room air temp fuel hits the burner, eliminating gelling of the oil.
Topic: Top Three Ways To Unclog Your Bathtub Drain Freshness: 3 days 5 hours ago Reply
sosewlinda@gmail.com wrote: two story apartment: top tub occasonally drains into bottom apartment bathtub. WHY???? I have snaked but it still happens. i do minor plumping repairs. this is new to me ,,,can you help?????
Topic: How To Fix Seven Types Of Leaky Faucets Freshness: 3 days 9 hours ago Reply
Larry wrote: I have a double handled Moen faucet in my bathroom. The hot side is leaking. I have tried replacing the o-rings on the cartridges……… ;.still leaks. So I swapped cartridges and it is still leaking from the hot side. I am baffled! Any advice???
Topic: Hayward Super Pump Repair Guide Freshness: 3 days 14 hours ago Reply
Joseph wrote: Hi Tracey, Have you checked the pump skimmer basket to make sure nothing is clogging the impeller? I would check that first and then check the motor bearings to see if they are seized ;-) Let me know if you need more help. Joseph
Topic: Hayward Super Pump Repair Guide Freshness: 3 days 15 hours ago Reply
Tracy Nicastro wrote: I have a Hayward Pump. It just stopped working 4 days ago. The breaker was tripped, we reset it, but as soon as we try to turn the pump on again, the breaker trips again. Any ideas? We are clueless. Thanks, Tracy
Topic: Stiebel Eltron Tempra 15 Electric Tankless Water Heater Review Freshness: 3 days 20 hours ago Reply
Jay Martin wrote: I would like infomation on instuation of an electric water heater. My main question would be if it can be installed in an enclosed closet or if it needs to be out in the open. I am drawing up plans for a small house and want to use a tankless waterheater. Not looking to buy until next year in the spring. Any infomation would be appricated. Thanks, jay
Topic: How To Fix Seven Types Of Leaky Faucets Freshness: 3 days 22 hours ago Reply
Redwood wrote: Hi Jody, Generally the leaking you are talking about would be caused by worn components in the shower valve. Several scenarios exist that could cause this and it would depend on if the water was running into the washer as the leak occurs or, if you were doing a hot wash load and the water heater was reheating. The first scenario where the water was filling the washer may be the result of a lower water pressure which on some valves such as Delta and Peerless use a rubber cup type of seat that uses water pressure to assist in sealing. The rubber seat is badly enough worn that there is no longer enough pressure to seal properly while the water is running....
Topic: EdenPURE Heater Review Freshness: 4 days 3 hours ago Reply
kathy wrote: BORIS AND OTHERS. I HAVE AN ELECTRIC FURNACE AND HEAT PUMP. I HAVE A RANCH HOUSE 8 ROOMS. OPEN FLOOR PLAN. IT IS INSULATED VERY GOOD. I AM STILL PLEASANTLY SURPRISED ABOUT THE EDENPURE. APPARENTLY YOU HAVE HAD A PROBLEM WITH THE COMPANY. THAT IS TOO BAD. I USUALLY GIVE EVERYONE A CHANCE . I WILL SEE ABOUT MY ELECTRIC BILL. MY NEICE HAS ONE IN HER BASEMENT, AND SHE LOVES IT. TO EACH HIS OWN.GOOD DAY
Topic: Whirlpool 80 Gallon Self Cleaning Electric Water Heater Review Freshness: 4 days 9 hours ago Reply
William wrote: I to got the 80 gal.ModelEE3Z80HD055V Whirlpool Lifetime Warranty. Love the the way it performs but I can’t get an Outside Insulation Jacket,or a Pan large enough to put under it. Still looking that’s what I’m doing now.
Topic: EdenPURE Heater Review Freshness: 4 days 23 hours ago Reply
Boris wrote: I somehow entered the wrong contact info in my post of yesterday. It is borisn86v – at – gmail . com, not borisn96v Kathy, if you have electric heat units on the walls with thermostats in each room, then I think it is safe for me to say that you have bought a redundant unit. Electric heat is 100% efficient and it doesn’t matter whether it comes from a $15 heater or built-in electric registers along the walls. As far as your house staying warm, one would have to know what the outside temp is, how much the built-in system is contributing and other factors. If you have a forced-air electric system, then you could save money by turning down the thermostat and heating an...
Topic: EdenPURE Heater Review Freshness: 4 days 23 hours ago Reply
Boris wrote: I somehow entered the wrong contact info in my post of yesterday. It is borisn86v – at – gmail . com, not borisn96v Kathy, if you have electric heat units on the walls with thermostats in each room, then I think it is safe for me to say that you have bought a redundant unit. Electric heat is 100% efficient and it doesn’t matter whether it comes from a $15 heater or built-in electric registers along the walls. As far as your house staying warm, one would have to know what the outside temp is, how much the built-in system is contributing and other factors. If you have a forced-air electric system, then you could save money by turning down the thermostat and heating an...
Topic: EdenPURE Heater Review Freshness: 4 days 23 hours ago Reply
Boris wrote: I somehow entered the wrong contact info in my post of yesterday. It is borisn86v – at – gmail . com, not borisn96v <> Kathy, if you have electric heat units on the walls with thermostats in each room, then I think it is safe for me to say that you have bought a redundant unit. Electric heat is 100% efficient and it doesn’t matter whether it comes from a $15 heater or built-in electric registers along the walls. As far as your house staying warm, one would have to know what the outside temp is, how much the built-in system is contributing and other factors. If you have a forced-air electric system, then you could save money by turning down the...
Topic: Baxi Condensing Boiler HT380 Review Freshness: 5 days 5 hours ago Reply
Nicholas Lamb wrote: Our Baxi 1.656 is almost 2 years old. When first installed it only made a loud click and a hushed whirring sound as the fan started up, Within 3 months it started to make a loud rumble when starting up. It is intermittent, but has continually been getting worse. It can now go on for 10 seconds and cycles up and down in volume. It sounds like an old car that almost stalls after turning on the ignition. I am sure it is exactly what is being described here and we can hear it in our Master bedroom which is 2 stories above the boiler and 25 feet away from the vertical flue. I have had the installer back for a total of 4 times, and it has never been improved...
Topic: EdenPURE Heater Review Freshness: 5 days 14 hours ago Reply
kathy wrote: I PURCHASED THE GEN 3 EDENPURE HEATER JUST THIS WK. I TURNED IT ON FULL POWER THEN WHEN THE HOUSE WAS WARM TURNED IT DOWN TO A LITTLE MORE THAN HALF POWER. I WAS PLEASANTLY SURPRISED THE HOUSE (8 ROOMS) WAS THE SAME TEMP THE NEXT MORN. 73 DEGREES. I AM WATCHING TO SEE WHAT MY ELEC BILL WILL BE THIS MONTH. IT USUALLY RUNS 270.00 I HAVE ELEC HEAT. AND A HEAT PUMP. I USUALLY HAVE TO KEEP IT SET ON 70′ JUST TO KEEP MILDLY WARM. WE’LL SEE. SO FAR SO GOOD. IT WOULD BE WORTH THE MONEY.
Topic: EdenPURE Heater Review Freshness: 5 days 20 hours ago Reply
Boris wrote: EdenPure is lying about several things. -The infomercial I saw tonight (11/14/09) shows an inexpensive electric heater on screen as it is explained how other heaters rob the air of oxygen and put out toxic fumes. This is a blatant lie when it comes to electric heaters as there is no combustion which is required to burn oxygen; fumes also come only from a combustion heater. Anyone using such a heater in their house could be in danger of asphyxiation unless properly installed to vent combustion fumes to the outside. -The EdenPure unit is 1500 watts and puts out appx 5000 BTUs but all electric heaters are 100% efficient so the claim (explicit or implied) that the EdenPure puts...
Topic: Weil McLain Ultra Series 2 Gas Fired Water Boiler Freshness: 6 days 4 hours ago Reply
Kirk wrote: Rich, The boost will be parameter 11 when you get into this program. Adjust that setting to zero (0) to turn the boost off. Remember to push store after changing the setting.
Topic: Weil McLain Ultra Series 2 Gas Fired Water Boiler Freshness: 6 days 8 hours ago Reply
Rich wrote: I am going to try that tomorrow.. this is at a rental house that I own. Question I had was is there a list off all the codes? I checked the control suppliment and they dont list any of these special codes. I was also looking for the code to turn off the boost. If I get this set up right i dont need the boost feature. I monitor all the temps with a prolipix thermostat. I can tell right away if there is no heat gain in the unit. http://www.weil-mclain.com/dow nloads/literature/ultragas/ult racontrolsupp.pdf
Recent Trackbacks:
- Rinnai R50LSi Tankless Water Heater Review: With the R50LSi you are getting a tankless water heater that is rated...
- Baquacil Vs Chlorine: that claim to be the best but there are two great systems that can live up to that claim, the...
- Top Flushing Toilet Awards 2009: Gerber Avalanche Super Toilet is the newest toilet in the Gerber Inventory. This...
- Little Giant Submersible Pump Buyers Guide: Little Giant 9S-CIM Sewage Ejector Pump is perfectly designed to help...
- Best Oil Fired Boilers 2009: Buderus G215 Oil Fired Residential Boiler is insulated with a 3″ thick thermal...