Comments on: LAARS Mini Therm Hydronic Boiler https://wetheadmedia.com/laars-mini-therm-hydronic-boiler-review/ Plumbing, Heating and Pool Repair Guides Tue, 06 Dec 2022 20:24:31 +0000 hourly 1 https://wordpress.org/?v=6.0.11 By: John Payne https://wetheadmedia.com/laars-mini-therm-hydronic-boiler-review/comment-page-1/#comment-38271 Tue, 06 Dec 2022 20:24:31 +0000 https://wetheadmedia.com/?p=5098#comment-38271 I purchased a Laars JVS 125 from a supplier in the metro Washington DC. Area last October 2021 and installed it that same month. Upon the homeowner firing it off this fall,2022, it started having intermittent flame failures. The only way to get the boiler back on was to cycle power to the boiler and the gas valve. The pilot assembly would light but the gas valve would not open. I replaced the gas valve and pilot assembly and the problem stopped. I turned in the old parts for warranty and was denied the claim. The boiler was not quite one month over a year from the install date. Come to find out the boiler was manufactured in 2019. Sat in a warehouse somewhere until I purchased it in October of 2021. The initial response from the factory was just that it was a 3 year old boiler. Until I told the local supplier to check their records on the sale. The local supplier then went back to the factory on the warranty parts which was again denied. One month out of warranty from the date of sale and install 10/30/21. Just a heads up if you are thinking of purchasing a LAARS boiler in the future.

]]>
By: Poker online https://wetheadmedia.com/laars-mini-therm-hydronic-boiler-review/comment-page-1/#comment-25129 Wed, 30 Sep 2020 06:02:00 +0000 https://wetheadmedia.com/?p=5098#comment-25129 You are so interesting! I don’t suppose I’ve truly
read anything like that before. So wonderful to discover someone
with genuine thoughts on this issue. Seriously.. many thanks for starting this up.
This website is something that is required on the web, someone with some originality!

]]>
By: Frank Delany https://wetheadmedia.com/laars-mini-therm-hydronic-boiler-review/comment-page-1/#comment-23874 Thu, 29 Sep 2016 21:10:40 +0000 https://wetheadmedia.com/?p=5098#comment-23874 I had the Laars Mini Therm JVS100 installed just after Hurricane Sandy and so far I’ve had 3 service calls. One for the expansion tank that went bad after 1 year. 2- Had to replace 2 stage gas valve (cost $500 parts and labor)3-Leaking relief valve twice. So far this unit has cost me over $1000 in repairs and it’s only 3 years old. Will never buy another Laars product again!

]]>
By: richard gibbons https://wetheadmedia.com/laars-mini-therm-hydronic-boiler-review/comment-page-1/#comment-3800 Wed, 27 Jan 2010 11:07:04 +0000 https://wetheadmedia.com/?p=5098#comment-3800 dear sirs, I have a mini therm 2 under floor heating system and have recently experienced clanking ( thumping) noise when it is operating. I purchased the home from the owner who said that the instructions for the heater had been misplaced. Could you please tell me if this problem that i am having can be fixed or send me the instructions for purging the system. the model # is JUS160 NDI, natural Gas, 30 PSI max for altitudes 5001 to 8000 feet. Could you also refer me to someone in the Alamogordo, NM area that installs and repairs your product. My address is 27 pueblo trail, alamogordo, NM 88310. tel # 702 306 4065. thank you in advanced. Richard Gibbons

]]>