<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
		>
<channel>
	<title>Comments on: Weil McLain Gold Series CGt Gas Fired Boiler</title>
	<atom:link href="http://wetheadmedia.com/weil-mclain-gold-series-cgt-gas-fired-boiler-with-tankless-heater/feed/" rel="self" type="application/rss+xml" />
	<link>http://wetheadmedia.com/weil-mclain-gold-series-cgt-gas-fired-boiler-with-tankless-heater/</link>
	<description>WeT HeaD Media Provides clear, easy to read Information for The Plumbing, Heating and Pool Industry.</description>
	<lastBuildDate>Thu, 18 Mar 2010 20:11:41 -0400</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9.2</generator>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
		<item>
		<title>By: mike</title>
		<link>http://wetheadmedia.com/weil-mclain-gold-series-cgt-gas-fired-boiler-with-tankless-heater/comment-page-1/#comment-3654</link>
		<dc:creator>mike</dc:creator>
		<pubDate>Sat, 23 Jan 2010 02:17:32 +0000</pubDate>
		<guid isPermaLink="false">http://wetheadmedia.com/?p=1001#comment-3654</guid>
		<description>I own a weil-Mclain gold series 2, it just cycles over and over it goes through the light cycles properly then shuts down then starts over again. produces just enough heat to take a couple of showers every couple of days. vents are clear hose trap is clear. flame does not get proven, has new ignitor. circulator runs continously                                                                                                                                                                                                                                                                                                                                                                                                                                                                         thank you Mike</description>
		<content:encoded><![CDATA[<p>I own a weil-Mclain gold series 2, it just cycles over and over it goes through the light cycles properly then shuts down then starts over again. produces just enough heat to take a couple of showers every couple of days. vents are clear hose trap is clear. flame does not get proven, has new ignitor. circulator runs continously                                                                                                                                                                                                                                                                                                                                                                                                                                                                         thank you Mike</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: joseph neigel</title>
		<link>http://wetheadmedia.com/weil-mclain-gold-series-cgt-gas-fired-boiler-with-tankless-heater/comment-page-1/#comment-2734</link>
		<dc:creator>joseph neigel</dc:creator>
		<pubDate>Fri, 06 Nov 2009 12:05:17 +0000</pubDate>
		<guid isPermaLink="false">http://wetheadmedia.com/?p=1001#comment-2734</guid>
		<description>I   have a CGT5 that  was installed in June 2009. The contractor was terrible. He built his business over 35 years ago and now let&#039;s his kids run it. Say no more. You all know the rest. The system is wrong for my home. Aside being installed off the kitchen when the noise of the venting is terrible, it does not send hot water to the back rooms. I am now working with another contractor trying to resolve the problem Wish me luck.

Lesson learned know your contractor&#039;s reputation NOW not in the past. And call in other contractors to hear there story on their unit.</description>
		<content:encoded><![CDATA[<p>I   have a CGT5 that  was installed in June 2009. The contractor was terrible. He built his business over 35 years ago and now let&#8217;s his kids run it. Say no more. You all know the rest. The system is wrong for my home. Aside being installed off the kitchen when the noise of the venting is terrible, it does not send hot water to the back rooms. I am now working with another contractor trying to resolve the problem Wish me luck.</p>
<p>Lesson learned know your contractor&#8217;s reputation NOW not in the past. And call in other contractors to hear there story on their unit.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: landon</title>
		<link>http://wetheadmedia.com/weil-mclain-gold-series-cgt-gas-fired-boiler-with-tankless-heater/comment-page-1/#comment-407</link>
		<dc:creator>landon</dc:creator>
		<pubDate>Fri, 06 Mar 2009 07:15:29 +0000</pubDate>
		<guid isPermaLink="false">http://wetheadmedia.com/?p=1001#comment-407</guid>
		<description>My Mother owns a Weil-McLain cgt boiler its about 5 years old, recently the heating system was intermintinly heating even after it was satisfiyed at 75 degress and then would completly stop heating. Called tec they relpaced the thermostate. I beleve was the wrong one problem still exsisted tec came the next day said it was the mixer box. said they had to order it. they returned again and exchanged the thermo again this time with the  same model we had in,  honeywell focus pro th6000 heating system went back to working normal. they removed this mixer box and now she has no hot water.  My thoughts are they did not troubleshoot the system properly. Q. could this mixer box have been the problem or was it the thermo?

Please help we are holding final payment, we are looking for credit on the thermostate, and return the old thermostate.

Thank You

Landon</description>
		<content:encoded><![CDATA[<p>My Mother owns a Weil-McLain cgt boiler its about 5 years old, recently the heating system was intermintinly heating even after it was satisfiyed at 75 degress and then would completly stop heating. Called tec they relpaced the thermostate. I beleve was the wrong one problem still exsisted tec came the next day said it was the mixer box. said they had to order it. they returned again and exchanged the thermo again this time with the  same model we had in,  honeywell focus pro th6000 heating system went back to working normal. they removed this mixer box and now she has no hot water.  My thoughts are they did not troubleshoot the system properly. Q. could this mixer box have been the problem or was it the thermo?</p>
<p>Please help we are holding final payment, we are looking for credit on the thermostate, and return the old thermostate.</p>
<p>Thank You</p>
<p>Landon</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: mike</title>
		<link>http://wetheadmedia.com/weil-mclain-gold-series-cgt-gas-fired-boiler-with-tankless-heater/comment-page-1/#comment-289</link>
		<dc:creator>mike</dc:creator>
		<pubDate>Wed, 04 Feb 2009 04:29:06 +0000</pubDate>
		<guid isPermaLink="false">http://wetheadmedia.com/?p=1001#comment-289</guid>
		<description>I have a well McClain gold series lp fired boiler.  The heating portion seems to work great but I cannot get more than 1 minute of domestic hot water on a good day.  I would like to know what direction I should go to correct this.  The boiler is not too old 6 or 7 years.  I can give you more information if you need it. I would appreciate  Any suggestions.  Thank You</description>
		<content:encoded><![CDATA[<p>I have a well McClain gold series lp fired boiler.  The heating portion seems to work great but I cannot get more than 1 minute of domestic hot water on a good day.  I would like to know what direction I should go to correct this.  The boiler is not too old 6 or 7 years.  I can give you more information if you need it. I would appreciate  Any suggestions.  Thank You</p>
]]></content:encoded>